KanexPro AUD-DTE-2CHAMP plugin for Q-SYS
Version 1.0.7

It controls the AUD-DTE-2CHAMP straight over the network. No other KanexPro software is needed.

How to install
1. Copy the .qplug file into Documents\QSC\Q-Sys Designer\Plugins on the Q-SYS Designer computer.
2. Restart Q-SYS Designer. The plugin is in the Schematic Elements list under Plugins > KanexPro.
3. Drag it into the design, select it, and set its properties (below). Then save it to the Core and run.

Properties
- IP Address: the AUD-DTE-2CHAMP's address on the control network.
- Port: 8000 (TCP, the unit's control port). Leave it unless the unit's own web page sets another.
- Poll Interval: how often, in seconds, it reads the unit back (0 = only after a change). Default 10.

The Status control shows OK once it is connected, and why if it is not.

What it controls (89 controls, every one with a pin)
- Source (level, each output)
- Volume (level, the unit)
- Volume a step (pick, the unit)
- Mute everything (on/off, the unit)
- Volume (level, each output)
- Mute (on/off, each output)
- Delay (ms) (pick, each output)
- Stereo (on/off, each pair)
- Gain (dB) (pick, each input)
- Mute (on/off, each input)
- EQ (pick, each output)
- Same EQ left and right (on/off, each pair)
- Clear the EQ (button, each output)
- Power (button, the unit)
- Standby after no sound (min, 0 = never) (level, the unit)
- Volume display (pick, the unit)
- ID light (pick, the unit)
- Find it (pick, the unit)
- Fan (pick, each n)
- Trigger input (button, the unit)
- Presets (button, the unit)
- Save (button, the unit)
- Clear a preset (button, the unit)
- Power (light, the unit)
- Firmware (reading, the unit)
- IP mode (reading, the unit)
- Address (reading, the unit)
- Subnet mask (reading, the unit)
- Gateway (reading, the unit)
- Control port (reading, the unit)
- Telnet port (reading, the unit)

Settings that only the unit's own web page has (its network, logins, firmware) are left to that page.

The guide for this plugin (install, properties, every control, the Status control,
troubleshooting) is KanexPro-AUD-DTE-2CHAMP-QSYS-Plugin-Guide-1.0.7.pdf, in this zip.