KanexPro MMX-8X8AUD plugin for Q-SYS
Version 1.0.5

It controls the MMX-8X8AUD straight over the network. No other KanexPro software is needed.

How to install
1. Copy the .qplug file into Documents\QSC\Q-Sys Designer\Plugins on the Q-SYS Designer computer.
2. Restart Q-SYS Designer. The plugin is in the Schematic Elements list under Plugins > KanexPro.
3. Drag it into the design, select it, and set its properties (below). Then save it to the Core and run.

Properties
- IP Address: the MMX-8X8AUD's address on the control network.
- Port: 8000 (TCP, the unit's control port). Leave it unless the unit's own web page sets another.
- Poll Interval: how often, in seconds, it reads the unit back (0 = only after a change). Default 10.

The Status control shows OK once it is connected, and why if it is not.

What it controls (94 controls, every one with a pin)
- Source (pick, each output)
- Send a picture (on/off, each output)
- Power (button, the unit)
- Presets (button, the unit)
- Save (button, the unit)
- Scaler (pick, each output)
- EDID (pick, each input)
- Sound back from the screen (ARC) (on/off, each output)
- Clear a preset (button, the unit)
- Lock the front panel (on/off, the unit)
- Beep (on/off, the unit)
- Front screen stays lit (pick, the unit)
- Signal (light, each input)
- Connected (light, each output)
- Power (light, the unit)
- Temperature (°C) (reading, the unit)
- Fan speed (reading, the unit)
- IP mode (reading, the unit)
- Address (reading, the unit)
- Subnet mask (reading, the unit)
- Gateway (reading, the unit)

Settings that only the unit's own web page has (its network, logins, firmware) are left to that page.

The guide for this plugin (install, properties, every control, the Status control,
troubleshooting) is KanexPro-MMX-8X8AUD-QSYS-Plugin-Guide-1.0.5.pdf, in this zip.